Difference between revisions of "Second-order Material Characterization"

From CleanEnergyWIKI
Jump to navigation Jump to search
m
Line 1: Line 1:
<table id="toc" style="width: 100%">
<table id="toc" style="width: 100%">
<tr>
<tr>
<td style="text-align: left; width: 33%">[[Second-order NLO Materials|Previous Topic]]</td>
<td style="text-align: left; width: 33%">[[Second-order NLO Material Design|Previous Topic]]</td>
<td style="text-align: center; width: 33%">[[Main_Page#Second-order Processes, Materials & Characterization |Return to Second-order Processes, Materials & Characterization Menu]]</td>
<td style="text-align: center; width: 33%">[[Main_Page#Second-order Processes, Materials & Characterization |Return to Second-order Processes, Materials & Characterization Menu]]</td>
<td style="text-align: right; width: 33%">[[THz Polymers| Next Topic]]</td>
<td style="text-align: right; width: 33%">[[THz Polymers| Next Topic]]</td>

Revision as of 14:30, 3 September 2009

Previous Topic Return to Second-order Processes, Materials & Characterization Menu Next Topic

Characterization

β, the first nonlinear polarizability depends on molecular structure, environment and measurement frequency. There are several tools that help us characterize the materials.

Hyper Rayleigh Scattering (HRS)

Hyper Rayleigh Scattering (aka Harmonic Light Scattering) is one method for measuring β.

The Hyper Rayleigh Scattering - Test best schematic

An incident laser generates a second harmonic signal, specifically the frequency double signal. This can be related to the beta of the sample using this formula:

<math>\frac {I_{sample}} {I_{solvent}} = \frac {N_{sample} \langle \beta^2 _{sample} \rangle + N_{solvent} \langle \beta^2_{solvent}\rangle} {N_{solvent} \langle \beta^2_{solvent}\rangle}\,\!</math>
HRS spectrum for 1.5 μm TCP1 in CHCl3

See Firestone 2004 [1].


See also Density Functional Theory

Electro-optic coefficient measurements

File:Tang mann r33.png
Teng-Man Testing configuration

We use the Teng - Man method to measure R33. R33 is an elipsometric measurement. You apply a voltage to the film while making the elipsometric measurements and looking for changes in the signal. You have to be careful with the kind of glass and the kind of tin oxide that is used. These measurements are made with the materials in a device configuration. The formula for R33

<math>r_{33}= \frac {3\lambda I_m (n^2 - sin^2 \theta) ^{1/2}} {4 \pi V_{poly}I_c n^2 sin^2 \theta}

\,\!</math> where

<math>I_m\,\!</math> is the amplitude of modulation
<math>V_{poly}\,\!</math> is the modulation voltage across EO polymer
<math>I_c\,\!</math> is the half intensity point
<math>n\,\!</math> is the refractive index of the polymer

and

<math>V_{poly}= V_{ACtot} \frac {d_{poly}} {d_{poly} + d_{clad}} \cdot \sqrt {\frac {\epsilon_{clad}} {\epsilon _{poly}}}\,\!</math>


See Khanarian 1996 [2]

See STC-MDITR research project 1.1 Measuring R33 with Interferometry


Previous Topic Return to Second-order Processes, Materials & Characterization Menu Next Topic
  1. K. A. Firestone, P. Reid, R. Lawson, S. H. Jang, and L. R. Dalton, “Advances in Organic Electro-Optic Materials and Processing,” Inorg. Chem. Acta, 357, 3957-66 (2004)
  2. Khanarian, et. al., JOSA B13, 1927 (1996)